CLOSE condition setting,
Adjust by buttons UP/DOWN from
or or .
Select the corresponding function, press
the SET button to save and exit the menu
setting.
The AUTO CLOSE function is turned on,
which means the door is controlled by the
AUTO CLOSE button on the control box.
Condition means: Only after the
door is opened to the open limit position,
the AUTO CLOSE function is effective and
starts timing.
Condition means: After the door
stops at any position when opening, the
AUTO CLOSE function is effective and
starts timing.
Condition means:No matter where
the door is open, as long as it is not at
the close limit position, it will
automatically close.
a. If the infrared function is
turned on, the AUTO CLOSE timing
will stop when the infrared is blocked
by an obstacle. After the obstacle
removed, it will continue the
previous timing and automatically
close the door.
b. When the door is about to
close, the courtesy light flashes for
warning.
c. When the door is about to
close, the warning light flashes to
warn.
d. Note: The flashing time of
the warning light follows the courtesy
light.
e. The AUTO CLOSE function
can only be used when the safety
protection device is used correctly