PRODUCT
GAS SUPPLY MANIFOLD PRESSURE
MODEL BURNERS GAS TYPE NOZZLE
PER BTU PER Kcal
TUBE PRESSURE
(in. W.C)
BTU kcal/h
Convection Oven
Range Line
FGR6CO
RANGE 6
NATURAL GAS #40
150.000 38.700
4
L.P. GAS #53 10
OVEN 1
NATURAL GAS #33 35.000 8.820 4
L.P. GAS #51 33.000 8.315 10
Standard Oven
Range Line
FGR4B
RANGE 4
NATURAL GAS #40
100.000 25.200
4
L.P. GAS #53 10
OVEN 1
NATURAL GAS #37 30.000 7.560 4
L.P. GAS #52 27.000 6.805 10
FGR6B
RANGE 6
NATURAL GAS #40
150.000 37.8 00
4
L.P. GAS #53 10
OVEN 1
NATURAL GAS #33 35.000 8.820 4
L.P. GAS #51 33.000 8.315 10
FGR10B
RANGE 10
NATURAL GAS #40
250.000 63.000
4
L.P. GAS #53 10
OVEN 2
NATURAL GAS
#37 30.000 7.560
4
#33 35.000 8.820
L.P. GAS
#52 27.000 6.805
10
#51 33.000 8.315
MOTOR SPEED
(RPM)
VOLTAGE
(V)
FREQUENCY
(Hz)
NOMINAL
CURRENT (A)
MOTOR ELECTRIC
POWER (W)
CIRCUT
BREAKER (A)
HIGH (1125 rpm)
115 60
3.3 372
5
LOW (1725 rpm) 3.7 392
HIGH (1125 rpm)
220 60
1.7 367
3
LOW (1725 rpm) 1.9 380
Warranty/Tech Support 800•722•6075
Service, Installation
& Care Manual
25
5.2 Technical Data
05. TECHNICAL SPECIFICATIONS
Convection Model