17G3 Cabinets - Service Manual
Refrigerant Charge
The refrigerant charge weight can be found on the serial label within the appliance. Where this is not available please refer to the table below. The
information below is correct time of printing but is subject to change without prior notice.
Evaporator Fan Motors
The appliance is tted with 2 speed evaporator fan motor(s). It is important that they are wired correctly to ensure optimum cooling and energy
performance from the appliance. High speed mode is active during compressor operation with low speed mode being active at all other times
subject to the parameter ‘FCM’.
Door Switch
The appliance is tted with a magnetic door switch located in the underside of the front cover. Where the door switch is open and following the
time set in parameter DAD, the controller will, indicate DO and an alarm will sound. At the point the door is opened the evaporator fan(s) will stop
and following the time set in parameter CSD relay 1 will open until such time as the door is closed.
EP700H 80gms
EP700M 80gms
EP700L 80gms
EP700G 95gms
EP700F 80gms
EP700SH 80gms
EP700SL 80gms
EP700P 110gms
EP1440H 140gms
EP1440M 150gms
EP1440L 150gms
EP1440G 140gms
EP700HH 65gms per system
EP700HL 65gms per system
EP700LL 65gms per system
EP700H2 80gms per system
EP700L2 80gms per system
EP700LL 65gms per system