12
Note: PV connection mode below is not allowed.
Step 2: DC Wiring
Turn off the DC switch.
Choose 12 AWG wire to connect the PV module.
Trim 6mm of insulation from the wire end.
Separate the DC connector as below.
Insert striped cable into pin contact and ensure all conductor strands are captured in the pin contact.
Crimp pin contact by using a crimping plier. Put the pin contact with striped cable into the corresponding
crimping pliers and crimp the contact.
Insert pin contact through the cable nut to assemble into back of the male or female plug. When you feel or
hear a “click” the pin contact assembly is seated correctly.
Unlock the DC connector
· Use the specified wrench tool.
· When separating the DC + connector, push the tool down from the top.
· When separating the DC - connector, push the tool down from the bottom.
· Separate the connectors by hand.