21
Note!
Please set-up the inverter if it is the first time to start-up. The above steps are for the regular
start-up of the inverter. If it is the first time to start up the inverter, you need to carry-out the
initial set-up of the inverter.
Warning!
Power to the unit must be turned on only after installation work has been completed.
All electrical connections must be carried out by qualified personnel in accordance
with legislation in force in the country of installation.
5.10 Auto-test
Auto test procedures:
1. Connect the inverter communication interface (COM) to computer via USB-RS485 converter.
2. Closed DC side circuit breaker and AC side circuit breaker.
3. Open the program Auto Test Tool.
4. Select the COM port and Baud rate, Click "Open" button to connect COM port.
5. Click "Start" button to start self test.
5.11 Inverter Switch Off
Please follow the below steps to switch off the inverter:
a) Switch off the inverter AC isolation switch.
b) Switch off the DC isolation switch and allow 5 minutes for the inverter to power down completely.