38
M1 Close Fault
The grid relay M1 keep close.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
M2 Close Fault
The grid relay M2 keep close.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
GridV Cons Fault
The grid voltage sample value between master and slave is not consistent.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
GridF Cons Fault
The grid frequency sample value between master and slave is not consistent.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
Dci Cons Fault
The dci sample value between master and slave is not consistent.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
Rc Cons Fault
The residual current sample value between master and slave is not consistent.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
RDSP SPI Fault
The communication between master and slave is fail.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
RDSP Smpl Fault
The slave sample detection circuit is failed.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
ARM EEPROM Fault
The manager eeprom is fault.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
Meter Lost Fault
The communication between meter and Inverter is interrupted.
Check if the communication cable between meter and Inverter is correctly and
well connected.
BMS Lost
The communication between BMS and Inverter is interrupted.
Check if the communication cable between BMS and Inverter is correctly and
well connected.
Bms Ext Fault
The communication between BMS and Inverter is interrupted.
Check if the communication cable between BMS and Inverter is correctly and
well connected.
Bms Int Fault
DIP switch at the wrong position;
The communication between battery packs is interrupted.
Move the DIP switch to the correct position;
Check if the communication cable between battery packs is correctly and well
connected.