31
maintain the inverter.
When the inverter is shut down, turn the DC switch to “OFF”, ensuring that the inverter is
completely powered off, and wait for at least 15 minutes.
Loosen the screws on the fan cover of the case.
Loosen the fan tray retention screws, unplug the connector cable and pull out the fan, use a
soft-bristled brush or vacuum cleaner to clean the fan or replace a damaged fan.
Fan maintenance must be done by professional personnel.
8. Decommissioning
8.1 Dismantling the Inverter
- Disconnect the inverter from DC Input and AC output. Wait for 15 minutes for the inverter to fully