EasyManua.ls Logo

FPT F34TE1W - Page 9

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(1) (1)
(1)
TheContinuouspoweristhatwhichageneratingsetiscapableofde-
liveringcontinuouslyforanunlimitednumberofhoursperyear,according
tothespeci󰘰edmaintenanceintervalsandunderstandardambientcon-
ditions.
(2) (2)
(2)
PrimePoweristhemaximumpoweravailablewithvariableloadsfor
alimitednumberofhours.Themeanpowerdeliveredduringaperiod
of24 24
24
h h
h
mustnotexceed80 80
80
% %
%
oftheprimepowerdeclaredbetweenthe
speci󰘰edmaintenanceintervalsandinstandardambientconditions.An
overloadof10 10
10
% %
%
ispermittedfor1 1
1
h h
h
every12 12
12
h h
h
ofoperation.
(3)Stand-bypoweristhemaximumpoweravailableforaperiodof500
hours/yearwithameanloadfactorof90 90
90
% %
%
ofthedeclaredstand-bypower.
Notypeofoverloadispermittedforthis.
Generalprescriptions
Itisseverelyprohibited,underpenaltyofcancellationofthewar-
rantyandoftheresponsibilitiesofFPT,tochangethecharacter-
isticsindicatedabove.
Failuretocomplycompletelyorpartiallywiththeserequirements
mayresultintheriskofseriousdamagetotheengineandmay
even,onoccasion,invalidatethewarranty
8