12
ENGINE TECHNICAL DATA N45 SM1A/SM1/
SM2A/SM2 - N45 TM1A/TM1/TM2A/TM2/TM2X
The technical code and serial number are indicated on a plate, which
is located on different parts of the engine, according to the model:
flywheel casing, tappet cover, other.
1) Excluding versions SM (*)Net power to the flywheel in compliance with ISO 8528.
C o de N 4 5 S M 1 A / S M 1 / S M 2 A / S M 2
N45 TM1A/TM1/TM2A/TM2/TM2X
Engine family F4
Cycle 4-stroke diesel
Number and arrangement
of cylinders
4, in line
Bore x stroke 104 x 132 mm
Total displacement 4,500 cm
3
Air system Supercharged and Aftercooled
(1)
Injection type Direct with rotating pump
Engine direction of rotation Anticlockwise (seen from flywheel side)
Speed regulator Mechanical
Dry weight
SM
TM
480 kg
500 kg
Electrical system 12 V
Accumulator/s
- capacity
- discharge current
100 Ah or above
650 A or above
Performance (*) N45 SM1A - N45 SM1
(STAGE 2)
Prime
Stand-by
53,5 kWm @ 1,500 rpm
59 kWm @ 1,500 rpm
(TIER 2)
Prime
Stand-by
59
kWm @ 1,800 rpm
65 kWm @ 1,800 rpm
Performance (*) N45 SM2A - N45 SM2
(STAGE 2)
Prime
Stand-by
66
kWm @ 1,500 rpm
73 kWm @ 1,500 rpm
(TIER 2)
Prime
Stand-by
65
kWm @ 1,800 rpm
72 kWm @ 1,800 rpm
Performance (*) N45 TM1A - N45 TM1
(STAGE 2)
Prime
Stand-by
77 kWm @ 1,500 rpm
85 kWm @ 1,500 rpm
Prime
Stand-by
86
kWm @ 1,800 rpm
95 kWm @ 1,800 rpm
Performance (*) N45 TM2A - N45 TM2
(STAGE 2)
Prime
Stand-by
88
kWm @ 1,500 rpm
96 kWm @ 1500 rpm
P r im e
Stand-by
97
kWm @ 1,800 rpm
107 kWm @ 1,800 rpm
Performance (*) N45 TM2X
(TIER 3)
Prime
Stand-by
86,5
kWm @ 1,800 rpm
95 kWm @ 1,800 rpm
WARNING
Any alteration of the above mentioned characteristics is strictly
prohibited, penalty invalidation of the guarantee and absence of all
liability on the part of FPT .