33
ENGLISH
6) The frequency with which operations are carried out will depend
on the working conditions and efficiency/wear of the product.
7) Required by oil vapour recirculation.
REQUIREMENTS
1. Do not disconnect the batteries with the engine running.
2. Do not carry out arc welding operations in the vicinity of the engine
without first removing electrical cables.
3. After each maintenance operation involving disconnection of the
battery/batteries, make sure that the terminals have been properly
locked onto the poles.
4. Do not use battery chargers to start the engine.
5. Disconnect the on-board network battery/batteries when
recharging.
6. Do not paint the appliances, components and electrical connectors
equipping the engine.
7. Disconnect the battery/batteries before any electrical operations.
8. Contact the Manufacturer before installing electronic equipment
on board (two-way radios and the like).
WARNING
The extraordinary maintenance operations described
hereunder fall within the exclusive competence of
manufacturer’s personnel or specialised personnel having
proper working tools and adequate protection devices. The
procedure and modality for carrying out these operations
are illustrated in the FPT Technical and Repair Manual.
WARNING
Do not execute any operation which may change the ignition pump’s
calibration.
The ignition pump’s calibration has been carried out in phase of
engine system test based on its final use or destination.