30
REFUELLING
(*)The amounts indicated relate to the standard configuration of the
engine only.
(**)Total capacity.
(1)Use a mixture of water and 50% PARAFLU 11 even during the
summer months. As an alternative to PARAFLU 11, use another
product that complies with international specifications SAE J 1034.
(2)Use lubricants that comply with international specifications ACEA
E3 - E5 (high power engines), API CF - CH4 (associated with fuels
with a percentage sulphur < 0.5%), MIL - L - 2104 F.
The viscosity level of oil to be used depending on surrounding
temperatures in given in the table provided in the appendix.
Oil consumption is considered acceptable when it reaches a
maximum of 0.5% of fuel consumption
CAUTION!
Do not carry out maintenance operations when the
electric power supply is turned on: always check to ensure
that the appliances are properly earthed. During diagnosis
and maintenance operations, make sure that your hands
and feet are dry, and whenever possible use insulating
stands.
CAUTION!
The conditions provoking the emergency power unit start
may suddenly occur. Whenever executing checks and
maintenance operations, strictly follow the safety
instructions prescribed by the unit’s Manufacturer and
power unit system’s outfitter to operate safely and prevent
injury.
Parts to be supplied N45
litres (kg)
N67
litres (kg)
Cooling circuit
(1)
engine
(*)
8,5 10,5
G-Drive
(**)
18,5 25,5
Lubrication circuit
(2)
total capacity
(3)
Periodic changing:
oil sump at minimum level
oil sump at maximum level
12,8 (11,8)
7 (6,5)
11,5 (10,5)
17,2 (15,8)
8,7 (8)
15,2 (14)
Fuel tank
(4)
- -