EasyManua.ls Logo

FRAM FDU-M12 - Auto Restart

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Error Codes:
EH60 - Humidity sensor error - Unplug the unit and plug it back in. If error repeats, call for service.
EH61 - Tube Temperature sensor of the evaporator error-- Unplug the unit and plug it back in. If error repeats,
call for service.
EH02 - Zero-crossing signal detection error; If error repeats, call for service;
EH03 - Indoor fan speed malfunction; If error repeats, call for service;
EH0b - Indoor PCB and display board communication error; If error repeats, call for service;
Protection Code:
P2 - Bucket is full or bucket is not in right position - Empty the bucket and replace it in the right position. On
some models, the water full light illuminates.
Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord.
Contact the service agents.
Other features
Bucket full light
Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper
position.
Auto defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run
until the frost disappears.
Auto shut off
The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in
the proper position.
For some models, the fan motor will continue to run for 30 seconds.
Fresh light
For some models, the ion generators energized and will help to purify the air inside.
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot be restart operation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
Auto-restart
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting
automatically when the power resumes.
Continuous dehumidifying mode
At continuous dehumidifying mode, the unit dehumidify continuously and cannot select humidity. Press
mode button to exit continuous dehumidifying mode.
Smart dehumidifying mode
At smart dehumidifying mode, the unit will automatically control room humidity in a comfortable range
45%~55% according to the room temperature. The humidity setting function will be invalid.