Clean Coils and Inspect Drawer Gaskets Quarterly RF 19 Q01
Document Part #19011151 – Rev. C – Revised 5/23/2018 ©McDonald’s Corporation · Planned Maintenance Manual · Revised January 2007 Page 1 of 2
Franke Foodservice Solutions
Convertible Cooler Freezer
RF19 Q
The condenser coil requires regular cleaning to maximize the unit’s performance. Failure to do so
could lead to premature refrigeration system failure, additional energy usage, quality and safety
risks for food product and voiding of warranty.
For 24-hour restaurants: during low volume period
Tools and supplies
Procedure
Flip the rocker switch to the
OFF position to power down
the refrigerated drawers.
Unplug the equipment from
the electrical outlet.
Panel is located on the lower
left side of the equipment.
Lift up on the panel and pull
away from the side of the
equipment to remove.
Louvers may have sharp
Using a soft-bristled brush,
remove all dirt, dust, and
debris from the coil.
Surfaces inside of the
condenser compartment may
be hot. Wear heat-resistant
gloves when accessing
condenser coil.
Always brush in the direction
Insert the six (6) tabs of the
louvered panel into the slots
around the condenser coil
opening, and then lower the
panel to lock it into place.
Louvers may have sharp
edges.