Troubleshooting
Page 32
Event no. Display message Solution
E003 Communication LP Restart machine. If the error continues: contact Service.
E008 Internal CAN Restart machine. If the error continues: contact Service.
E014, 015, 018, 019, 027, 028 Temperature sensor Restart machine. If the error continues: contact Service.
E016 Temp. difference Restart machine. If the error continues: contact Service.
E017, 021, 029 Over temperature Restart machine. If the error continues: contact Service.
E022 to 024 Heater timeout Restart machine. If the error continues: contact Service.
E030 Coffee post-heating Status message. No action necessary.
E040 to 043 Motor timeout Restart machine. If the error continues: contact Service.
E050 to 057 Checking card Remove card. Checking card (correct card?). Try again.
E058 to 061 Writing card Remove card. Checking card (clean it if necessary). Try again.
E090 Maint. required Contact Service for maintenance.
E099 Water filter Contact Service to replace water filter.
E110, 111 Flowmeter error If the error continues for a prolonged period: restart machine, contact Service if necessary.
E121 Add ground coffee Fill ground coffee container
E140 Calibrate store Contact Service.
E141 Frequency store Contact Service.
E160 Battery low Contact Service.
E200 to 203 Communication CS Only with accounting systems. Restart machine. If the error continues: contact Service.
E210, 211 Accounting CAN Only with accounting systems. Restart machine. If the error continues: contact Service.
E142 Add cleaner Connect new tank with detergent.
Troubleshooting
If a problem occurs, your Spectra X-XL will give you instructions. Events and information are shown on
the display. Should you be unable to resolve a problem despite all best efforts, please contact our ser-
vice department.
Help with Machine Errors