• Betweenthewatermainsandthewaterinletpipeoftheappliance,theremustbeataptostopthewaterflowifnecessary
(2 -
Pict
.3).
• Thewatermainspressuremustbewithintherangeof1 and 6 bar.
• Ifthisrequirementisnotmet,pleaseconsultthemanufacturer.
• Theapplianceissuppliedwithoutaplug.Itissupposedtobedirectlyconnectedtotheelectricmainsandtherefore,itisnecessary
to fit a single-pole switch with contact opening of 3 mm or more beforehand, according to the regulations in force
(1 -
Pict
.3).
• Thedrainpipeoftheappliancemustbedirectlyconnectedtoasuitableopendrainsiphon,previouslyinstalledbythecustomer(3
- Pict.3). Do not fit the drain pipe into basins or buckets placed under the counter as this will increase the possibility of forming dirt
deposits and as a result, the spread of bacteria
.
Attention!
The appliance is supplied without water in the boiler. This is to prevent serious damage if the appliance is exposed to low
temperatures. The appliance must only be supplied with cold drinking water.
Attention!
For appliances operating with gas, the gas supply tap must be fitted in an easily accessible place (4 - Pict. 3), so as to be able
to shut off the gas supply if necessary.
Regularly check the expiry date on the gas pipe connecting the system and the appliance and have it replaced by the Service
Centre before this date.