EasyManua.ls Logo

Franklin Electric FACT Series User Manual

Franklin Electric FACT Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
APPLICATION
SAFETY
CAREFULLY READ THESE SAFETY MESSAGES.
CAUTION
DO NOT OPERATE THIS PUMP DRY!
Review instructions before operating.
IMPORTANT: READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THE PUMP.
These pumps may be direct-coupled or belt driven from a suitable
power source - electric motor, gas engine, etc. They are intended
for installations where the vertical distance from the pump to water
surface does not exceed 7.5m (25 ft.) In all installations, friction
losses in the piping must be taken into consideration. Pump models
FACT-5 and FACT-6 should not be used for pumping liquid fertilizer.
Pump model FACT-8 can be used for liquid fertilizer if equipped with
the high temperature (Viton) seal.
INSTALLATION
(a) LOCATION: The pump should be installed in a location that
provides adequate drainage, room for servicing, and protection
from freezing. A proper foundation is necessary to maintain
the alignment between pump and power source. To reduce
friction losses and provide maximum capacities, the location of
the pump should be such that a minimum of suction piping is
required.
(b) SUCTION PIPE: It is recommended that only new, clean pipe
or hose be used and the size be the same as the pump suction
tapping. If the pump is installed any appreciable distance away
from the source of water supply, the suction pipe should be
increased by one size. The suction pipe must always slope
upwards from the water source to the pump to avoid air pockets
in the line. In cases where the pump has to be reprimed often, and
it is not necessary that a lot of water be delivered, it is advisable
to use a 90° or 45° elbow on the suction line. This enables the
pump to prime sooner and also prevents kinking of the hose.
In cases where a maximum volume of water is required over a
prolonged period of time, the suction line should be led almost
horizontally to the pump. Non-toxic thread compound should be
used on all pipe joints and connections should be thoroughly
tightened. A foot valve should be connected to the bottom end
of the suction pipe and must be submerged at all times.
PERFORMANCE
MODEL RPM HP
TOTAL HEAD IN FEET
10 20 30 40 50 60 80 100 120 140
CAPACITY IN GPM
FACT-5
3450 1-1/2 66 65 62 58 53 38 18
2250 1/3 42 21
FACT-6
3450 2-1/2 90 88 85 80 66 47 17
1750 1/2 50 37 11
FACT-8
3450 5 170 168 164 155 135 122 88 55
1750 1 93 78 59
Complete pressure and ow data is available in the Product Speci cation Sheets and Performance Curve section.
FACT SERIES END SUCTION CENTRIFUGAL
PUMP (FOR BELT OR COUPLING DRIVE)
OWNER'S MANUAL
PUMP
WELL CASING
SUCTION LINE
FOOT VALVE
PRIMING FITTING
POWER
SOURCE
DRAIN
PLUG
DISCHARGE PIPE
Fig. 1
Question and Answer IconNeed help?

Do you have a question about the Franklin Electric FACT Series and is the answer not in the manual?

Franklin Electric FACT Series Specifications

General IconGeneral
BrandFranklin Electric
ModelFACT Series
CategoryWater Pump
LanguageEnglish

Summary

FACT Series Centrifugal Pump Manual

Important Safety and Operation Precautions

Crucial safety instructions and warnings for operating the pump.

Pump Application and Performance Overview

Details on the intended uses, limitations, and performance data of the pump.

Installation Guidelines and Requirements

Guidance on proper pump installation, including location and suction piping.

Pump Installation Details

Foundation, Alignment, Rotation, and Speed Settings

Covers essential installation aspects like foundation, shaft alignment, rotation, and operating speed.

Pump Operation and Priming Procedures

Critical Priming and Startup Steps

Explains the vital priming process, startup procedures, and warnings against dry operation.

Pump Draining and Storage Instructions

Instructions for draining the pump for protection and proper storage to prevent damage.

Pump Maintenance Procedures

Lubrication, Disassembly, and Reassembly Guide

Details on lubrication, step-by-step disassembly, and reassembly of pump components.

Pump Component Diagrams

Assembly Illustrations for FACT-5/6 and FACT-8

Illustrates the assembly components and their arrangement for FACT-5/6 and FACT-8 models.

Pump Parts Identification

FACT-5 and FACT-6 Parts List and Exploded View

Exploded view diagram and part numbers for FACT-5 and FACT-6 pump models.

Pump Parts Identification

FACT-8 Parts List and Exploded View

Exploded view diagram and part numbers for the FACT-8 pump model.

Pump Troubleshooting Guide

Troubleshooting Pump Performance Issues

Addresses common problems like failure to pump, reduced capacity, and loss of prime with solutions.

Troubleshooting Mechanical and Seal Defects

Diagnoses mechanical issues, noises, and seal leaks, providing corrective actions.

Limited Warranty Information

Warranty Terms, Exclusions, and Liability Limits

Details warranty scope, exclusions, liability limits, and buyer responsibilities.