Table 2. Error Codes
Table 3. Fault Warning Codes
RPM Message
Display Display Probable Cause
E01 NO DATA >Datalink cable not connected / connected to wrong port
>Broken wire / bad connector contact on datalink cable
E02 NO RESP No responce to control signal
E03 NO RPM >Datalink cable not connected / connected to wrong port
>Engine not running / ignition key on
>Broken wire / bad connector contact on alternator cable
E04 N/A N/A
E05 NO PSR Pressure sensor not detected
E06 N/A N/A
E07 N/A N/A
E08 TRANS T’ >Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective temperature sensor
E09 ENG OIL’ >Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective pressure sensor
E10 ENG T’ >Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective temperature sensor
RPM Message
Display Display Description
F01 N/A
F02 N/A
F03 HI RPM High RPM
F04 Pump Hot Pump overheat
F05 Pump cavitation
F06 Tran Temp High transmission temperature
F07 Low Batt Low battery voltage
F08 Hi Batt High battery voltage
F09 Low Oil Low engine oil pressure
F10 Eng Temp High engine coolant temperature