WIRING
Primary Display
1
4 5
8
Primary Display
Connector
Pin Description
1 Power 9-30 VDC
2 Ground
3 Sensor 5 VDC
4 Sensor Signal
5* Buzzer Ground (150mA)
6 Display Signal Out
7 Datalink (+)
8 Datalink (–)
Standard Harness
Primary Display
Module
Deutsch Plug
DTM06-8S
Primary Display
Module
To
Pressure
Sensor
Power
Figure 8. Primary Display Wiring
*Note: When the TankVision primary is used to
control a remote valve, Foam Fill, or Auto Tank
system, pin 5 does not provide a ground for a
buzzer. The primary display is programmed from
the factory with a control output on pin 5 for each
of these special systems. These displays are not
interchangable.
Pressure Sensor Connector
Supply
Voltage
5 VDC
Output
Signal
Ground