Why is my Friedrich 2007 Air Conditioner not cooling properly?
- JJoshua MartinezJul 28, 2025
There are several reasons why your Friedrich air conditioner might not be cooling effectively. It could be an undersized unit, in which case you should refer to an industry-standard sizing chart. Check if the thermostat is open or inoperative; set it to the coldest position and test it. A dirty filter or dirty/restricted condenser or evaporator coil can also cause this issue, so clean them as recommended. Ensure good air circulation by adjusting the discharge louvers and using a high fan speed. For applicable models, make sure the fresh air or exhaust air door is closed. Finally, low capacity due to undercharge or a compressor not pumping properly could be the cause; check for leaks and repair them, and check the compressor's amperage draw against the nameplate.