36 PB
INSTALLATION
Power and Wiring
Capacity size Wire Diameter(AWG)
Condenser / Interconnecting Wire
Circuit Breaker Capacity Rating
9k-12k 14 AWG 600V / 14-4 AWG 600V THHN 15A
18k 12 AWG 600V / 14-4 AWG 600V THHN 20A
24-36K 10 AWG 600V / 14-4 AWG 600V THHN 30A
Fig. 435
