Technical Information
6HUYLFH0DQXDO
&RROLQJDQG+HDWLQJ'DWD6KHHWLQ5DWHG)UHTXHQF\
Rated cooling
condition(
o
F)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (
o
F) T2 (
o
F)
80/67 95/–
MWM09Y1J
MRM09Y1J
0.8~1.1
54 to 57 106 to 109 Super High High 48
MWM12Y1J
MRM12Y1J
50 to 54 109 to 113 Super High High 77
Rated heating
condition(
o
F)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (
o
F) T2 (
o
F)
70/60 47/43
MWM09Y1J
MRM09Y1J
37~38
98 to 100 36 to 39 Super High High 54
MWM12Y1J
MRM12Y1J
107 to 111 32 to 37 Super High High 78
,QVWUXFWLRQ
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Cooling:
Heating:
Indoor side noise when blowing
Outdoor side noise when blowing
60
60
60 80 100
50
50
40
40
40
30
30
20
20
20
10
0
0
Indoor Fan Motor Rotating Speed
Noice/dB(A)
Noice/dB(A)
low
Middle
High Super High
Compressor frequency/Hz
09K 12K 09K 12K
1RLVH&XUYH

Table of Contents

Other manuals for Friedrich MRM09Y1J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MRM09Y1J and is the answer not in the manual?

Friedrich MRM09Y1J Specifications

General IconGeneral
BrandFriedrich
ModelMRM09Y1J
CategoryAir Conditioner
LanguageEnglish

Related product manuals