39
TO CORRECTPOSSIBLE CAUSE
PROBLEM
Repair, clean or replace as required.
Evaporator drain pan cracked or
obstructed.
Water in compressor area.
Obstructed condenser coil.
Fan blade and slinger ring improperly
positioned.
Detach shroud from pan and coil. Clean and
remove old sealer. Reseal, reinstall and check.
Steam clean.
Adjust fan blade to 1/2" clearance from condenser
coil.
Outside water leaks.
High indoor
humidity.
TO CORRECT
POSSIBLE CAUSE
PROBLEM
Adjust louvers for best possible air circulation
Operate in "Fan-Auto (MoneySaver)" position.
Advise customer.
Insufficient air circulation in air condi-
tioned area.
Oversized unit.
Inadequate vapor barrier in building
structure, particularly floors.