Service Manual
95992013_00
Single Package Vertical Heat Pump System
R-410A Refrigerant
THE EXPERTS IN ROOM AIR CONDITIONING
VHA - 18K25RTQ, 18K34RTQ, 18K50RTQ, 18K75RTQ
VHA - 18R25RTQ, 18R34RTQ, 18R50RTQ, 18R75RTQ
18K
24K
VHA - 24K25RTQ, 24K34RTQ, 24K50RTQ, 24K75RTQ, 24K10RTQ
VHA - 24R25RTQ, 24R34RTQ, 24R50RTQ, 24R75RTQ, 24R10RTQ
VHA - 09K25RTQ, 09K34RTQ, 09K50RTQ
VHA - 09R25RTQ, 09R34RTQ, 09R50RTQ
9K
12K
VHA - 12K25RTQ, 12K34RTQ, 12K50RTQ
VHA - 12R25RTQ, 12R34RTQ, 12R50RTQ

Table of Contents

Questions and Answers:

Friedrich VERT-I-PAK VHA12K50RTQ Specifications

General IconGeneral
Cooling Capacity (BTU/h)12000
Heating Capacity (BTU/h)12000
Energy Efficiency Ratio (EER)11.0
RefrigerantR-410A
Voltage (V)208/230
Phase1
Compressor TypeRotary
Frequency60 Hz
Airflow (CFM)400
Sound Level (dB)52

Summary

INTRODUCTION

Important Safety Information

Crucial safety guidelines for qualified technicians and safe operation of the equipment.

Personal Injury Or Death Hazards

Details potential hazards to personnel, emphasizing safety precautions and warnings.

Electrical Hazards

Outlines risks associated with electrical components, wiring, and connections.

Refrigeration System Repair Hazards

Specific hazards related to handling refrigerants and pressurized systems.

SPECIFICATIONS

OPERATION

Sequence of Operation

Describes the unit's operational flow during power-up, fan, and emergency heat modes.

Defrost Mode Operation

Covers defrost calibration, demand defrost, activation, and operation sequences.

REMOVE AND INSTALL THE CHASSIS

EXTERNAL STATIC PRESSURE

TROUBLESHOOTING

Control Diagnostic Modes

Interpreting LED indicators for diagnosing control board faults and system issues.

COMPONENT TESTING

Reversing Valve Operation

Describes the function and operation of the 4-way reversing valve.

Testing Reversing Valve Solenoid Coil

Procedure for testing the solenoid coil continuity and ground resistance.

Checking The Reversing Valve

Methods for checking if the reversing valve shifts correctly between modes.

Compressor Checks

Tests for locked rotor voltage, running amperage, and overload status.

Checking Compressor Efficiency

Assesses compressor efficiency by checking pressures, temperatures, and current.

Heating Element and Limit Switches

Testing procedures and specifications for heating elements and limit switches.

Evaporator Blower Motor and Control Board

Diagnostic flowchart for testing the evaporator blower motor and its control board.

R-410A SEALED SYSTEM REPAIR

Refrigerant Charging

Guidance on proper refrigerant charging, effects of under/overcharging, and system diagnosis.

Sealed System Method of Charging/Repairs

Step-by-step procedure for charging and repairing sealed refrigeration systems.

Undercharged Refrigerant Systems

Symptoms, diagnosis, and potential causes of an undercharged refrigerant system.

Overcharged Refrigerant Systems

Symptoms, diagnosis, and potential causes of an overcharged refrigerant system.

Restricted Refrigerant System

Diagnosis and symptoms of partial and complete restrictions in the refrigerant system.

Compressor Replacement

Procedure for replacing a compressor, including system preparation and charging.

Compressor Replacement: Burnout Procedure

Special procedure for compressor replacement following a burnout event.

Replace The Reversing Valve

Steps for safely removing and replacing the reversing valve.

R-410A REFRIGERANT SYSTEM REPAIR

TXV Replacement

Instructions for removing and installing the Thermal Expansion Valve (TXV).

WIRING DIAGRAMS