Service Manual
95992013_00
Single Package Vertical Heat Pump System
R-410A Refrigerant
THE EXPERTS IN ROOM AIR CONDITIONING
VHA - 18K25RTQ, 18K34RTQ, 18K50RTQ, 18K75RTQ
VHA - 18R25RTQ, 18R34RTQ, 18R50RTQ, 18R75RTQ
18K
24K
VHA - 24K25RTQ, 24K34RTQ, 24K50RTQ, 24K75RTQ, 24K10RTQ
VHA - 24R25RTQ, 24R34RTQ, 24R50RTQ, 24R75RTQ, 24R10RTQ
VHA - 09K25RTQ, 09K34RTQ, 09K50RTQ
VHA - 09R25RTQ, 09R34RTQ, 09R50RTQ
9K
12K
VHA - 12K25RTQ, 12K34RTQ, 12K50RTQ
VHA - 12R25RTQ, 12R34RTQ, 12R50RTQ

Table of Contents

Questions and Answers

  • A
    Ashley HobbsAug 6, 2025
    What to do if the high pressure switch is open on my Friedrich Heat Pump?
    • G
      Gloria JohnsonAug 6, 2025
      If the high pressure switch is open in your Friedrich Heat Pump, it could be due to a faulty pressure switch or the discharge pressure being too high. Check the connection points and confirm system pressures and operation. If operating in cooling mode, ensure the outdoor condensing fan motor is running.
  • X
    xreynoldsAug 10, 2025
    What causes a high pressure switch lockout in a Friedrich VERT-I-PAK VHA12K50RTQ Heat Pump?
    • D
      Debra CollinsAug 10, 2025
      If the high pressure switch lockout occurs on your Friedrich Heat Pump, it could be caused by a faulty pressure switch or excessively high discharge pressure. Begin by checking the connection points. Next, verify the system pressures and overall operation, taking corrective measures as necessary. If the unit is in cooling mode, ensure that the outdoor condensing fan motor is functioning correctly.
  • M
    maria96Aug 14, 2025
    Why is the low pressure switch open on my Friedrich Heat Pump?
    • T
      Tina RodriguezAug 14, 2025
      If the low pressure switch is open on your Friedrich Heat Pump, it could be due to a faulty pressure switch or the suction line pressure being too low. Check the connection points and confirm system pressures and operation, addressing any issues found. Also, if in cooling mode, ensure the indoor blower is running.
  • T
    Taylor ReedAug 18, 2025
    What does it mean when the low pressure switch lockout occurs on a Friedrich VERT-I-PAK VHA12K50RTQ?
    • D
      David MaloneAug 18, 2025
      If a low pressure switch lockout occurs with your Friedrich Heat Pump, the possible cause is a faulty pressure switch or suction line pressure that is too low. Start by confirming the connection points. Then, check the system pressures and operation, and address any issues. If the unit is cooling, verify that the indoor blower is running.
  • C
    Christina ClarkAug 23, 2025
    How to fix a coil sensor failure on a Friedrich VERT-I-PAK VHA12K50RTQ Heat Pump?
    • X
      xjohnsonAug 23, 2025
      If your Friedrich Heat Pump displays a coil sensor failure, it means an open or shorted sensor has been detected. First, check the connection points. Then, use an ohmmeter to test the sensor to see if it's open (OL) or shorted (0.0 Ohms). If the sensor tests ok, replace the board. Refer to Appendix 1 (Thermistor resistor values).
  • B
    bethcisnerosAug 27, 2025
    What causes an ambient sensor failure in a Friedrich VERT-I-PAK VHA12K50RTQ Heat Pump?
    • L
      Lawrence McleanAug 27, 2025
      If your Friedrich Heat Pump is showing an ambient sensor failure, this indicates that an open or shorted sensor has been detected. Begin by checking all connection points. Next, use an ohmmeter to check the sensor for an open (OL) or shorted (0.0 Ohms) circuit. If the sensor appears to be functioning correctly, the next step is to replace the board. For reference, see Appendix 1 (Thermistor resistor values).
  • J
    Jamie ParkerAug 31, 2025
    How to troubleshoot a Friedrich VERT-I-PAK VHA12K50RTQ with a control fault (no power)?
    • C
      Christopher BruceAug 31, 2025
      If your Friedrich Heat Pump is experiencing a control fault and has no power, confirm the incoming voltage. If voltage is present, replace the board.

Summary

INTRODUCTION

Important Safety Information

Crucial safety guidelines for qualified technicians and safe operation of the equipment.

Personal Injury Or Death Hazards

Details potential hazards to personnel, emphasizing safety precautions and warnings.

Electrical Hazards

Outlines risks associated with electrical components, wiring, and connections.

Refrigeration System Repair Hazards

Specific hazards related to handling refrigerants and pressurized systems.

SPECIFICATIONS

OPERATION

Sequence of Operation

Describes the unit's operational flow during power-up, fan, and emergency heat modes.

Defrost Mode Operation

Covers defrost calibration, demand defrost, activation, and operation sequences.

REMOVE AND INSTALL THE CHASSIS

EXTERNAL STATIC PRESSURE

TROUBLESHOOTING

Control Diagnostic Modes

Interpreting LED indicators for diagnosing control board faults and system issues.

COMPONENT TESTING

Reversing Valve Operation

Describes the function and operation of the 4-way reversing valve.

Testing Reversing Valve Solenoid Coil

Procedure for testing the solenoid coil continuity and ground resistance.

Checking The Reversing Valve

Methods for checking if the reversing valve shifts correctly between modes.

Compressor Checks

Tests for locked rotor voltage, running amperage, and overload status.

Checking Compressor Efficiency

Assesses compressor efficiency by checking pressures, temperatures, and current.

Heating Element and Limit Switches

Testing procedures and specifications for heating elements and limit switches.

Evaporator Blower Motor and Control Board

Diagnostic flowchart for testing the evaporator blower motor and its control board.

R-410 A SEALED SYSTEM REPAIR

Refrigerant Charging

Guidance on proper refrigerant charging, effects of under/overcharging, and system diagnosis.

Sealed System Method of Charging;Repairs

Step-by-step procedure for charging and repairing sealed refrigeration systems.

Undercharged Refrigerant Systems

Symptoms, diagnosis, and potential causes of an undercharged refrigerant system.

Overcharged Refrigerant Systems

Symptoms, diagnosis, and potential causes of an overcharged refrigerant system.

Restricted Refrigerant System

Diagnosis and symptoms of partial and complete restrictions in the refrigerant system.

Compressor Replacement

Procedure for replacing a compressor, including system preparation and charging.

Compressor Replacement: Burnout Procedure

Special procedure for compressor replacement following a burnout event.

Replace The Reversing Valve

Steps for safely removing and replacing the reversing valve.

R-410 A REFRIGERANT SYSTEM REPAIR

TXV Replacement

Instructions for removing and installing the Thermal Expansion Valve (TXV).

WIRING DIAGRAMS

Friedrich VERT-I-PAK VHA12K50RTQ Specifications

General IconGeneral
Cooling Capacity (BTU/h)12000
Heating Capacity (BTU/h)12000
Energy Efficiency Ratio (EER)11.0
RefrigerantR-410A
Voltage (V)208/230
Phase1
Compressor TypeRotary
Frequency60 Hz
Airflow (CFM)400
Sound Level (dB)52