Service Manual
95992013_00
Single Package Vertical Heat Pump System
R-410A Refrigerant
THE EXPERTS IN ROOM AIR CONDITIONING
VHA - 18K25RTQ, 18K34RTQ, 18K50RTQ, 18K75RTQ
VHA - 18R25RTQ, 18R34RTQ, 18R50RTQ, 18R75RTQ
18K
24K
VHA - 24K25RTQ, 24K34RTQ, 24K50RTQ, 24K75RTQ, 24K10RTQ
VHA - 24R25RTQ, 24R34RTQ, 24R50RTQ, 24R75RTQ, 24R10RTQ
VHA - 09K25RTQ, 09K34RTQ, 09K50RTQ
VHA - 09R25RTQ, 09R34RTQ, 09R50RTQ
9K
12K
VHA - 12K25RTQ, 12K34RTQ, 12K50RTQ
VHA - 12R25RTQ, 12R34RTQ, 12R50RTQ

Table of Contents

Questions and Answers

  • L
    lauren07Aug 6, 2025
    What to do if the high pressure switch is open on my Friedrich VERT-I-PAK VHA18K34RTQ?
    • N
      Nicholas FernandezAug 6, 2025
      If the high pressure switch is open in your Friedrich Heat Pump, it could be due to a faulty pressure switch or the discharge pressure being too high. Check the connection points and confirm system pressures and operation. If operating in cooling mode, ensure the outdoor condensing fan motor is running.
  • H
    huffchelseyAug 10, 2025
    What causes a high pressure switch lockout in a Friedrich VERT-I-PAK VHA18K34RTQ Heat Pump?
    • M
      Mike MooreAug 10, 2025
      If the high pressure switch lockout occurs on your Friedrich Heat Pump, it could be caused by a faulty pressure switch or excessively high discharge pressure. Begin by checking the connection points. Next, verify the system pressures and overall operation, taking corrective measures as necessary. If the unit is in cooling mode, ensure that the outdoor condensing fan motor is functioning correctly.
  • W
    William CoxAug 15, 2025
    Why is the low pressure switch open on my Friedrich VERT-I-PAK VHA18K34RTQ Heat Pump?
    • C
      Carlos HornAug 15, 2025
      If the low pressure switch is open on your Friedrich Heat Pump, it could be due to a faulty pressure switch or the suction line pressure being too low. Check the connection points and confirm system pressures and operation, addressing any issues found. Also, if in cooling mode, ensure the indoor blower is running.
  • J
    Jorge WhiteAug 18, 2025
    What does it mean when the low pressure switch lockout occurs on a Friedrich VERT-I-PAK VHA18K34RTQ Heat Pump?
    • D
      Daniel MarshallAug 18, 2025
      If a low pressure switch lockout occurs with your Friedrich Heat Pump, the possible cause is a faulty pressure switch or suction line pressure that is too low. Start by confirming the connection points. Then, check the system pressures and operation, and address any issues. If the unit is cooling, verify that the indoor blower is running.
  • J
    Jason Hansen VAug 23, 2025
    How to fix a coil sensor failure on a Friedrich Heat Pump?
    • D
      David JohnstonAug 25, 2025
      If your Friedrich Heat Pump displays a coil sensor failure, it means an open or shorted sensor has been detected. First, check the connection points. Then, use an ohmmeter to test the sensor to see if it's open (OL) or shorted (0.0 Ohms). If the sensor tests ok, replace the board. Refer to Appendix 1 (Thermistor resistor values).
  • W
    William MartinAug 27, 2025
    What causes an ambient sensor failure in a Friedrich Heat Pump?
    • C
      Curtis KleinAug 27, 2025
      If your Friedrich Heat Pump is showing an ambient sensor failure, this indicates that an open or shorted sensor has been detected. Begin by checking all connection points. Next, use an ohmmeter to check the sensor for an open (OL) or shorted (0.0 Ohms) circuit. If the sensor appears to be functioning correctly, the next step is to replace the board. For reference, see Appendix 1 (Thermistor resistor values).
  • A
    angelagrahamSep 1, 2025
    How to troubleshoot a Friedrich VERT-I-PAK VHA18K34RTQ with a control fault (no power)?
    • S
      samantha79Sep 1, 2025
      If your Friedrich Heat Pump is experiencing a control fault and has no power, confirm the incoming voltage. If voltage is present, replace the board.

Summary

Introduction

Important Safety Information

Provides essential safety warnings, hazard symbols, and precautions for handling the equipment.

Equipment Identification

Details on locating and understanding model and serial number labels for unit identification.

Model Number Identification Guide

Explains the meaning of each digit and letter in the unit's model number.

Specifications

Electrical Specifications

Presents comprehensive data on voltage, amperage, wattage, and fuse/breaker requirements.

General Specifications

Lists key performance metrics including cooling/heating capacity, SEER2, EER2, and COP2.

Required Minimum Clearances

Specifies minimum distances needed around the unit for safe and effective installation.

Wall Opening Dimensions

Provides exact measurements for wall cut-outs for plenum and return air access.

Operation

Sequence of Operation

Details the unit's operational flow, including power-up, modes, and sensor functions.

Troubleshooting

Control Diagnostic Modes

Explains how to interpret LED indicators on the control board to diagnose faults.

Component Testing

Compressor Checks

Guides for performing electrical tests (resistance, voltage) and mechanical checks on the compressor.

R-410 A Sealed System Repair

Refrigerant Charging

Explains the importance and methods for correctly charging the system with R-410A refrigerant.

Compressor Replacement

Provides detailed procedures and safety warnings for replacing the unit's compressor.

Wiring Diagrams