INSTALLATION
Wall Plenum Installation
13
Wall Plenum Installation
Field Supplied Parts:
Sealant, attachment screws, and ashing
are eld supplied. Silicone sealant is recommended.
VPAWP1-8 adjusts for walls up to 4”- 8” thick.
VPAWP1-14 adjust for walls up to 8” - 14” thick
All installations are similar.
Flashing
1”-3” Screws to
attach the plenum
assembly to the wall
studs
Sealant
Shim
A
B
Parts included in Plenum kit:
Outside Plenum Half (Part A)
Inside Plenum Half (Part B)