www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352
All about the
Use & Care
Care and Cleaning
.............................................. 13
Energy Saving Ideas ........................................... 13
(June 2009)
Product Registration
...........................................................
5
5 gnigakcaP
Normal Sounds .................................................... 5
.............................................
6 serutaeF renoitidnoC riA .......................................
Important Safety Instructions ............................... 2-4
21-6snoitcurtsnI gnitarepO .........................................
of your
Room Air Conditioner
Before You Call................................................... 14
Major Appliance Limited Warranty........................ 15
16120300A18814

Other manuals for Frigidaire FFRE063WA1

Question and Answer IconNeed help?

Do you have a question about the Frigidaire FFRE063WA1 and is the answer not in the manual?

Summary

Important Safety Instructions

Power Cord Safety and Detection Device

Information on the power cord's current detection device and prohibitions against tampering.

Electrical Safety and Grounding Requirements

Emphasizes proper grounding and the use of grounded receptacles to prevent shock hazards.

Critical Safety Precautions for Operation

Details essential safety measures to prevent injury, fire, and accidents during operation and installation.

More Safety Instructions

General Safety Precautions for Use

Lists precautions to avoid injury or damage to the unit and surrounding property during operation.

Power Cord Current Device Test

Guides the user on how to test the power cord's safety feature and its correct operation.

Flammable Refrigerant and General Cautions

Flammable Refrigerant Safety Warnings

Covers safety warnings and procedures for handling flammable refrigerants used in the appliance.

General Cautions and User Responsibility

Outlines cautions for users, children, and emphasizes manufacturer responsibility for damaged cords.

Air Conditioner Features and Operation

Air Conditioner Operating Modes

Advanced Operating Functions

Specialized Operating Modes

Timer and Remote Sensing

Operation Status and Controls

Fault Code Interpretation

Explains fault codes, specifically addressing the 'AS' code indicating sensor failure.

Before You Call for Service

Troubleshooting: Unit Not Operating

Solutions for when the air conditioner fails to power on or respond.

Troubleshooting: Cooling Performance Issues

Addresses issues like insufficient cooling, ice formation, and room temperature problems.

Troubleshooting: Noise and Water Issues

Solutions for abnormal noises and water dripping from the unit during operation.

Troubleshooting: Remote & Temperature Settings

Resolves issues with remote sensing and achieving the desired room temperature.

Summary

Important Safety Instructions

Power Cord Safety and Detection Device

Information on the power cord's current detection device and prohibitions against tampering.

Electrical Safety and Grounding Requirements

Emphasizes proper grounding and the use of grounded receptacles to prevent shock hazards.

Critical Safety Precautions for Operation

Details essential safety measures to prevent injury, fire, and accidents during operation and installation.

More Safety Instructions

General Safety Precautions for Use

Lists precautions to avoid injury or damage to the unit and surrounding property during operation.

Power Cord Current Device Test

Guides the user on how to test the power cord's safety feature and its correct operation.

Flammable Refrigerant and General Cautions

Flammable Refrigerant Safety Warnings

Covers safety warnings and procedures for handling flammable refrigerants used in the appliance.

General Cautions and User Responsibility

Outlines cautions for users, children, and emphasizes manufacturer responsibility for damaged cords.

Air Conditioner Features and Operation

Air Conditioner Operating Modes

Advanced Operating Functions

Specialized Operating Modes

Timer and Remote Sensing

Operation Status and Controls

Fault Code Interpretation

Explains fault codes, specifically addressing the 'AS' code indicating sensor failure.

Before You Call for Service

Troubleshooting: Unit Not Operating

Solutions for when the air conditioner fails to power on or respond.

Troubleshooting: Cooling Performance Issues

Addresses issues like insufficient cooling, ice formation, and room temperature problems.

Troubleshooting: Noise and Water Issues

Solutions for abnormal noises and water dripping from the unit during operation.

Troubleshooting: Remote & Temperature Settings

Resolves issues with remote sensing and achieving the desired room temperature.

Overview

This document describes the use and care of a Frigidaire room air conditioner, providing instructions for operation, maintenance, and troubleshooting.

Function Description

The Frigidaire room air conditioner is designed to cool and dehumidify a room. It features an electronic control panel and a remote control for convenient operation. The unit can be set to various modes, including Cool, Auto, Dry, and Fan Only, to suit different comfort needs. It also includes an Eco feature for energy-efficient operation and a Sleep feature for comfortable nighttime cooling. The unit's power supply cord incorporates a current detection device to reduce the risk of fire.

Usage Features

Turning the Unit On/Off: To turn the unit on, press the ON/OFF button. The unit will initially run in Cool mode with the Eco feature activated and Auto fan speed. To turn the unit off, press the ON/OFF button again.

Operating Modes:

  • Cool Mode: This is the primary cooling mode. The fan remains on continuously while the compressor cycles on and off to maintain the set room temperature. The temperature can be adjusted between 62°F (17°C) and 86°F (30°C).
  • Auto Mode: In this mode, the unit automatically combines Cool mode with Auto fan speed. The fan speed cannot be manually selected in this mode.
  • Dry Mode: This mode functions as a dehumidifier while also cooling the room. The fan speed is fixed at "Lo," and the temperature can be adjusted between 62°F (17°C) and 86°F (30°C).
  • Fan Only Mode: Use this mode when cooling is not desired, such as for room air circulation or to exhaust stale air. In this mode, the display shows the actual room temperature, not the set temperature. Any fan speed can be selected.

Fan Speed Adjustment: The fan speed can be adjusted among four settings: Auto, Lo (Low), Med (Medium), and Hi (High). This is not applicable in "Auto" or "Dry" modes, or when the Sleep feature is activated. In Auto fan speed, the fan starts at Low and adjusts based on room temperature.

Temperature Setting: The desired temperature can be set using the UP (∧) or DOWN (∨) buttons on the control panel or remote. The unit will maintain the set temperature within a range of 62°F (17°C) to 86°F (30°C). The control is capable of displaying temperature in both Fahrenheit and Celsius.

Eco Feature: When the Eco feature is active, if the room temperature falls below the set temperature, the fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10-minute intervals until the room temperature rises above the set temperature, at which point the compressor restarts. This feature can be activated or deactivated by pressing the Eco button, but it is invalid in Fan Only mode.

Sleep Feature: In Sleep mode, the unit automatically selects Auto fan speed. The selected temperature will increase by 2°F after 30 minutes, and then by another 2°F after an additional 30 minutes. This new temperature is maintained for 7 hours before returning to the originally selected temperature. Sleep mode can be canceled at any time by pressing the "Sleep," "Fan speed," or "Mode" button.

Timer Feature (Delay Stop/Start): The timer allows for delayed stopping or starting of the unit. Press the Timer button, then use the UP (∧) or DOWN (∨) arrows to set the delay time in 0.5-hour increments up to 10 hours, and then 1-hour increments up to 24 hours. The setting is confirmed automatically after 5 seconds. The timer can be canceled by pressing and holding the Timer button for 2 seconds or by pressing the ON/OFF button.

Remote Sensing Feature (on some models): This feature, activated via the remote control in cooling mode, allows the remote to act as a thermostat. Point the remote towards the unit and press the Remote Sensing button. Use the UP (∧) or DOWN (∨) buttons on the remote to set the desired temperature. The unit's control panel will illuminate to indicate signal reception. The remote's display shows the temperature at its location. If the unit does not receive a signal for 7 minutes, the feature halts until a signal is received again. It can be terminated by pressing the Remote Sensing button again or the main ON/OFF button.

Fresh Air Vent Control (on some models): The Fresh Air Vent allows control over air circulation:

  1. Vent Closed: Recirculates inside air.
  2. Fresh Air: Draws fresh air into the room.
  3. Vent Open: Exchanges air from the room.

Air Directional Louvers: Slider-type louvers allow directing airflow Up or Down and Left or Right. Drag the adjuster tablet for Left/Right direction and pivot horizontal louvers for Up/Down direction.

Light Feature: The display and all LED indicators on the control panel can be turned off by pressing the "Light" button on the remote control. If any other button is pressed, the unit will beep, and the display/LEDs will illuminate for 5 seconds before turning off again. Pressing the "Light" button again or unplugging the unit cancels this setting.

Power Supply Cord Current Device: The power supply cord has a current detection device. To test it, plug in the AC, press the TEST button (the RESET button will pop out), then press the RESET button (it will engage). A light on the plug head indicates power supply. Do not use this device to turn the unit on or off. Always ensure the RESET button is pushed in for correct operation.

Maintenance Features

Air Filter Cleaning: The air filter should be checked at least once a month. Trapped particles can accumulate and cause frost on cooling coils. To clean:

  1. Push the vent handle to the Vent Closed position (if applicable).
  2. Open the front panel.
  3. Grasp the filter by the center and pull it up and out.
  4. Wash the filter with liquid dishwashing detergent and warm water, rinse thoroughly, and gently shake off excess water. Ensure it is thoroughly dry before replacing.
  5. Alternatively, vacuum the filter clean. When replacing, ensure the tabs on the air filter are on the upper part and face outward.

Check Filter Feature: An LED light illuminates after 250 hours of operation as a reminder to clean the air filter. To reset this reminder after cleaning, press the "Filter Reset" button, and the light will turn off.

Cabinet Cleaning: Unplug the air conditioner before cleaning to prevent shock or fire hazards. The cabinet and front can be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Avoid harsh cleaners, wax, or polish on the cabinet front. Wring excess water from the cloth before wiping around controls to prevent damage. Plug in the air conditioner after cleaning.

Winter Storage: If storing the unit for winter, remove it carefully following the installation instructions. Cover it with plastic or return it to its original carton.

Troubleshooting: The manual provides a "Before You Call" section with common occurrences and their solutions, such as the unit not operating, air not feeling cold enough, ice formation on coils, rapid cycling, noise, and water dripping. This helps users identify and resolve minor issues before contacting service.

Frigidaire FFRE063WA1 Specifications

General IconGeneral
TypeWindow Air Conditioner
Cooling Capacity6, 000 BTU
Voltage115V
Dimensions (W x H x D)19 x 12.5 x 21.5 inches
Weight52 lbs
Noise Level52 dB
RefrigerantR-32
Cooling Area250 sq. ft.
Fan Speeds3
Power Supply115V
Filter TypeWashable
Installation TypeWindow