Pleasecheckthefollowingbeforecallingforservice:
Placeonecupofwaterinaglassmeasuringcupinthemicrowaveovenandclosethedoorsecurely.
OperatethemicrowaveovenforoneminuteatHIGH100%.
A Doesthemicrowaveovenlightcomeon?
B Doesthecoolingfanwork?(PutyourhandattopaboveDisplay.)
C Doestheturntablerotate?(Itisnormalfortheturntabletoturnineitherdirection.)
D Isthewaterinthemicrowaveovenwarm?
If"NO"is the answer to any of the above questions,
please check electrical outlet, fuse and/or circuit
breaker, if they are functioning properly, CONTACT
YOUR NEAREST ELECTROLUX AUTHORIZED SER-
VICER.
A microwave oven should never be serviced by a
"do=it=yourself" repair person.
YES NO
YES NO
YES NO
YES NO
1. If time appearing in the display is counting down
very rapidly, check Demonstration Mode on page 25
and cancel.
2. If the oven is set for more than 40 minutes at 80,
90 or 100 percent power level, after the first 40
minutes the power level will automatically adjust
itself to 70 percent power to avoid overcooking.
AC Line Voltage: Single phase 120V, 60Hz, AC only
AC Power Required: 1500W 13.5 A (for FGMV154CLF, FGMV153CLB/W
CGMV154CLF,CGMV153CLB/W)
Output Power*: 900 W
Output Power*(convection): 1450 W
Frequency: 2450 MHz (Class B/Group2)**
Outside Dimensions (including handle): 29.88 "(W) x 15.75 "(H) x 15.04"(D)
Cavity Dimensions: 20.24 "(W) x 8.94 "(H) x 13.94"(D)
Microwave oven Capacity***: 1.5 Cu.Ft.
Cooking Uniformity: Turntable
Weight: Approx. (net) 63.93 Ib, (gross) 69.45 Ib
Work/Night Light: 2 bulbs 30w each (incandescent light bulbs)
Oven Light: 1 bulb 30w (incandescent light bulbs)
* The International Electrotechnical Commission's standardized method for measLring output wattage. This test method
is widely recognized.
** This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the InternationalStandard CISPR11.
*** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC - Federal Communications Commission Authorized.
DHHS
®
0®
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in
Canada.