ENGLISH
14
Description of display
Display Status Remedy
Reverse connection of charging
clips
Connect charging clips correctly
Excess temperature-battery
charger too hot
Allow battery charger to cool
down
Fan is defective Consult Fronius dealer
General failure of battery char-
ger
Consult Fronius dealer
Technical Data
Acctiva Professional Acctiva Professional 42
Supply voltage 230 V AC, 50/60 Hz 230 V AC, 50/60 Hz
Nominal power 860 W 860 W
Charging voltage 6 / 12 / 24 V 12 / 24 / 36 V
Charging current 0,6 - 30 A 0,6 - 20 A
Nominal charging capacity 3 - 300 Ah 3 - 200 Ah
Chargeable cells 3 / 6 / 12 6 / 12 / 18
Duty cycle 100 % 100 %
Charging characteristic IUoU / IUIoU IUoU / IUIoU
Protection category IP 31 IP 31
Weight 2000 g 2000 g
Dimensions (l x h x w) 285 x 70 x 142 mm 285 x 70 x 142 mm
manual specified setting for
24V-battery
Acctiva Professional
42
automatic battery voltage
selection
manual specified setting for
12V-battery
manual specified setting for
36V-battery
4. Confirm selected battery voltage by pressing the Start-Stop button (10)
Battery is defective
Setting of the battery charger is
wrong
Check battery
Check setting: Ampere-hours,
voltage
Appliances are connected to the
battery
Switch off the appliances or
select operating mode „Standard
charging“