OPT/i CU level
sensor
This option is available for the following devices:
- CU 1100i
- CU 1100i /460 V
- CU 1100i /MV
- CU 1100i /MV RVP
- CU 1200i Pro /MC
The option is installed as standard on the CU 1400i Pro/MC cooling unit.
The level sensor monitors the level of coolant in the cooling unit.
If both the OPT/i CU flow temperature sensor and the OPT/i CU level sensor options
are installed in the cooling unit, the level sensor works as follows:
- If the coolant drops below the minimum level:
- the power source outputs a warning
- the welding current is not interrupted
- the cooling unit remains operational
If just the OPT/i CU level sensor option is installed in the cooling unit, the level sensor
works as follows:
- If the coolant drops below the minimum level:
- the power source outputs an error message
- the level sensor interrupts the welding current
- the cooling unit switches off
OPT CU front
coolant connec-
tions
This option is available for the following devices:
- CU 1100i
- CU 1100i /460 V
- CU 1100i /MV
- CU 1100i /MV RVP
- CU 1200i Pro /MC
- CU 1400i Pro /MC
The option can be used in conjunction with the following power sources:
- TPS 320i C
- iWave 300i - 500i
OPT/i CU Torch
deflate
This option is available for the following devices:
- CU 1100i
- CU 1100i /460 V
- CU 1100i /MV
- CU 1100i /MV RVP
- CU 1200i Pro /MC
- CU 1400i Pro /MC
Prerequisites for using the OPT/i CU Torch deflate option:
- OPT/i CU flow temperature sensor installed in the cooling unit
- OPT CU coolant connections installed in the front of the cooling unit
The option facilitates emptying/filling the torch hosepack, e.g. when changing the torch
body.
The power source does not have to be switched off during this process.
23
EN