Fronius CU 800i - Disconnecting cooling unit from power source

Fronius CU 800i
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disconnect the cooling unit from the power source
Safety
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
Before starting work, switch off all devices and components involved and disconnect
them from the grid.
Secure all devices and components involved so they cannot be switched back on.
WARNING!
Danger from hot coolant.
This can result in serious burns or scalding.
Before carrying out any work, allow the coolant to cool to +25 °C / +77 °F.
WARNING!
Danger from coolant leakage.
This can result in serious personal injury and damage to property.
If there is any coolant on the exterior of the cooling unit, remove it immediately.
Make sure that no coolant gets into the interior of the cooling unit.
Disconnecting
the cooling unit
from the power
source
1
Disconnect the coolant hoses from the cooling unit
2
WARNING!
Danger from short circuits.
This can result in serious personal injury and damage to property.
Dirt and damage can cause short circuits on the cooling unit connection.
After dismantling the power source, always close the cooling unit connection cover
on the underside of the power source.