CU 1200i Pro /MC
CU 1200i Pro /MC
Supply voltage 24 V DC
Current consumption 2.1 A
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1200 W
800 W
1400 W
1100 W
Max. delivery head 50 m
(164 ft. 0.5 in.)
Max. delivery rate 1.8 l/min
(0.47 gal./min [US])
Max. pump pressure 5 bar
(72.51 psi
Pump Gear pump
Pump service life up to 20,000 hrs
Coolant capacity 6 l
(1.59 gal. [US])
Degree of protection IP 23
Dimensions l/w/h 710/300/230 mm
(27.95/11.81/9.06 in.)
Weight (without coolant) 12 kg
(26.46 Ib.)
Flow monitoring
(sensor)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Coolant temperature monitoring Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Level sensor*
(functionality depends on the options in-
stalled in the device)
Warning or error message
Mark of conformity CE, CSA
* Optional