Changing coolant
(CU 800i, 1100i,
and 1400i)
WARNING!
Danger from welding current and accidental ignition of an arc.
This can result in serious injury and damage to property.
Disconnect the ground earth connection between the welding system and the work-
piece.
Remove the wire electrode from the welding torch being used.
Depending on the system, remove the wirespool or the basket-type spool from the
power source or the wirefeeder.
NOTE!
To avoid environmental pollution due to improper coolant disposal:
The coolant must not be disposed of in the public sewage system.
Dispose of coolant in accordance with the applicable local and national regulations.
1
WARNING!
Danger from coolant leakage.
This can result in serious personal injury and damage to property.
Seal off the coolant hose as soon as it is pulled out of the coolant pump connection.
Immediately remove any coolant that does get into the device or spills onto the ex-
terior of the device.
62