EasyManua.ls Logo

Fronius CU 800i - General technical information; CU 800 i and CU 800 i;460 V specifications

Fronius CU 800i
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
General The cooling capacity of a cooling unit depends on
- Ambient temperature
- Delivery head
- Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
CU 800i,
CU 800i /460 V
CU 800i
Mains voltage 400 V AC
Mains voltage tolerance -10% / +10%
Grid frequency 50/60 Hz
Current consumption 0.7 A
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
800 W
500 W
1160 W
730 W
Max. delivery head 35 m
(114 ft. 9.95 in.)
Max. delivery rate 3.5 l/min
(0.92 gal./min [US])
Max. pump pressure 4.2 bar
(60.92 psi)
Pump Centrifugal pump
Pump service life approx. 10,000 hrs
Coolant capacity 4.5 l
(1.19 gal. [US])
Degree of protection IP 23
Dimensions l/w/h 706/260/219 mm
(27.8/10.24/8.62 in.)
Weight (without coolant) 11.2 kg
(24.69 Ib.)
Flow monitoring*
(sensor)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Coolant temperature monitoring* Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Mark of conformity CE
* Optional