Information about
the coolant
CAUTION!
Danger from using non-permitted coolant.
This can result in serious damage to property.
▶
Only use coolant available from the manufacturer.
▶
Do not mix different coolants.
▶
When changing the coolant, make sure all the coolant is replaced.
▶
When switching from ethanol-based coolant to FCL 10 coolant, Change Kit FCL10
must be used and the instructions provided must be followed.
Warning notices
on the device
The cooling unit is fitted with safety symbols and a rating plate. The rating plate and
safety symbols must not be removed or painted over. The symbols warn against operat-
ing the equipment incorrectly, as this may result in serious injury and damage.
4 bar (0.4 MPa) 800 W
P
1l/min
2~
50/60 Hz
IEC 60 974-2/-10 Cl.A IP 23
0.7 A
U
1
400 V
p
max
I1
pmax
I1
Welding is dangerous. The following basic requirements must be met to
ensure the equipment is used properly:
- Welders must be sufficiently qualified
- Suitable protective equipment must be used
- All persons not involved must be kept at a safe distance from the cool-
ing unit and the welding process
Do not use the functions described here until you have thoroughly read
and understood the following documents:
- these operating instructions
- all the operating instructions for the system components, especially
the safety rules
Do not dispose of used devices with domestic waste. Dispose of them
according to the safety rules.
Information on
leaks
The following information on leaks does not apply to the FK 2500 Rob, FK 2500 MV Rob.
18