Poor-quality weld properties
Incorrect welding parameters
Check settings
Incorrect ground connection
Check ground connection and terminal for polarity
Cause:
Remedy:
Cause:
Remedy:
Welding torch gets very hot
Welding torch is inadequately sized
Observe duty cycle and load limits
For water-cooled systems only: Coolant flow too low
Check water level, water flow rate, water contamination, etc. Coolant pump
blocked: Switch on the shaft of the coolant pump at the gland using a
screwdriver
For water-cooled systems only: C-C parameter is set to "OFF".
In the Setup menu, set the "C-C" parameter to "Aut" or "ON".
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy: