"Program level preferences”
Access
1
Select the desired operating mode TIG/Electrode
2
Switch off power source
3
Switch on the power source while holding down the operating mode (3) or process
(4) button.
4
Release mode (3) or process (4) button
Select and
change setup
parameters
1
Select the desired parameter using the operating mode (3) or process (18) button
2
Change the parameter value using the torch trigger
Available TIG
parameters
NOTE!
If problems occur with sensitive devices in the immediate vicinity, increase the welding
parameter HFt to up to 0.4 s.
GAS Gas pre-flow
Unit: Seconds
Setting range: 0 - 20
Factory setting: 0.4
G - L Gas-Low
Gas post-flow at minimum welding current (minimum gas post-flow time)
Unit: Seconds
Setting range: 2 - 26
Factory setting: 5
G - H Gas-High
Gas post-flow time at maximum welding current
Unit: Seconds
Setting range: 2 - 26
Factory setting: 15
The setting value for G-H only applies if the maximum welding current is actually
set. The actual value results from the momentary welding current. At medium
welding current, for example, the actual value is half the set value for G-H.
UPS UpSlope
Time for transition from starting current I
S
to welding current I
H
Unit: %
Setting range: DC: 0 - 100 / AC: 30 - 100 of the main current I
H
Factory setting: DC: 29 / AC: 50
SCU Start-Current
Starting current
Unit: Seconds
Setting range: 0 - 20
Factory setting: 0.4