FS0507T PN 60711000162
on, the power is automatically turned off.
2) Please keep charging time above 8 hours.
The maximum charging time is 12 hours. When the battery cannot be fully charged
within 12 hours, the charging end indicator (yellow) flashes.
3) When the battery power is insufficient, the output power may decrease. Please
charge as early as possible. When the power of this unit is turned on, the power meter
in the red area indicates that it needs to be charged.
4) Please confirm whether the battery fluid is sufficient. If it is insufficient, please add
distilled water or battery fluid in time. The battery fluid should be between MIN-MAX
marked on the side of the battery.
The BPC-12-120 battery does not require battery fluid replenishment.
Warning
● When charging, please unplug the cable of the charger (the reel and extension
cable are the same) to prevent the charging cable from overheating. . When using the
reel and extension cable, please confirm the allowable capacity of the cable in advance
to avoid overcurrent. . Worst case scenario could cause fire
● Please charge in a place with good ventilation conditions.
● Do not charge near open flames.
● Charging when the battery fluid is low may cause toxic gas, which may cause harm
to people or surrounding metal materials. Stop charging immediately.
5.5.6 Charging mode
Ability to choose to change the charging mode.
1) Charging mode display
After the charger is turned on, the charging mode is displayed 4 times in a row on the
display.
Tip
● If the charging mode (open type / closed type) is set incorrectly, the battery life
may be reduced.
● When changing the battery, make sure that the settings are correct.
2) How to select the charging mode
① Turn on the charger switch while pressing the selection button. Enter the charging
mode selection interface.
② The display and all indicators are on.