Command: OCRECF n
Description:
Select the Output Resolution to use.
Parameters:
n - Output Resolution: n[0 – 7];
VGA|SVGA|XGA|720p|SXGA|1280x768|1365x768|1365x1024
Example:
OCRECF 2: Select output format to be XGA.
OCRECF T?: Translates the query output to return [0 – 7].
Command: OFRATE n
Description:
Select the Output Frame Rate to use.
Parameters:
n - Output Frame Rate: n[0 – 2], 59.94Hz | 50Hz | 75Hz
Example:
OFRATE 0: Select output frame rate to be 59.94Hz.
Command: OSYNC n op
Description:
Adjusts the Output Sync type for any of the three outputs.
Parameters:
n - Output Sync: n[1-5], -C|+H+V|+H-V|-H+V|-H-V
op - Output connector to make the change on: [B|H|P], where
B = BNC Output connector
H = Main HD15 Output connector
P = Preview HD15 Output connector
Example:
OSYNC 3 H: Adjusts the Output Sync value to be +H-V on the Main
HD15 connector.
Command: OTPM m typ inv bx gr
Description:
Enables/Disables the Output Test Pattern and selects Test Pattern options.
Parameters:
m - Output TP Enable: m[0-3],
OFF|ON (Main Only)|ON (Preview Only)|ON (Both Scalers)
typ - Test Pattern Type: typ[0-5] H Gray Ramp|H Gray Scale|Burst|Color Bars|Black|Live Mode
inv - Test Pattern Inversion: inv[0|1] OFF|ON
bx - Test Pattern Raster Box: bx[0-3] OFF|ON
gr - Test Pattern Grid: gr[0|1] OFF|ON
Example:
OTPM 2 3 0 1 0: Enables the Test Pattern to be shown on Preview.
Color Bars have been selected with inversion off, raster box on
and grid off.
Command: PFSD n sclr
Description:
Progressive Frame Sequence Detection. This command will allow the detection of 3-2 pulldown to
be enabled or disabled.
Parameters:
n - n[0|1], Disable or Enable
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview