Section 6 Parameter Settings
31 FT702LT Flat Front Wind Sensor Manual
6.1.2 Query Commands
Figure 28 lists the commands that may be sent to the FT702LT from the host computer that are used to QUERY
the wind sensor’s latest readings or configuration.
Serial interface baud rate
1200, 2400, 4800, 9600, 19200, 38400
Enabled or Disabled
Update interval, 0.2-12000 seconds
Wind velocity data format
Number of hours of runtime*
Enable or Disable
Speed filter length, 1-64*
Direction filter length, 1-64*
Setpoint Temperature, 0°C to 44°C
Setpoint Temperature, 44°C to 55°C*
Percentage of heater current, 0% to 100%
Internal sensor temperature, 00°C to
±99°C,
Heater Delay Time, 4s to 999s *
Current Limit, 0.1A to 6.0A*
Undervoltage Limit, 9V to 17V*
Listener and talker identifiers
Listener ID = xx
Talker ID = xx
Min & Max Speeds Recorded
Enabled or Disabled*
Wind speed table record*
Table label*
6.4.19 &
6.4.20 &
6.4.21 &
6.4.22 &
6.4.23
Matches Saved to Current User
Parameters*
Wind Speed, Direction and Sensor Status
Figure 28: Query Commands
#
Feature only available from build version 20 and above
* Feature only available from build version 22 and above