Instruction Manual
5000G11S/P11S
Standard RS485 Interface
Caution

After reading and understanding this
instruction manual, install, connect
(wire), operate and maintain the
inverter.

Please consider to ensure that this
instruction manual reaches the
persons who actually use this
product.

Keep this instruction manual up to
disposing the inverter.

The product is subject to change for
improvement etc. without notice.
Fuji Electric Co., Ltd. INR-HF51190a-E
!
!!
!

Questions and Answers:

Fuji Electric frenic 5000g11s Specifications

General IconGeneral
Input Frequency50/60 Hz
Enclosure RatingIP20
Control MethodV/f control, Sensorless vector control
Cooling MethodForced Air Cooling
Communication ProtocolsModbus, Profibus, DeviceNet, Ethernet
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short circuit
Ambient Temperature-10°C to +50°C
Humidity95% RH or less (non-condensing)
Altitude1000 m above sea level or less

Summary

Introduction and Safety

Foreword

Introduction to the manual and its purpose, covering communication specifications and usage instructions.

Safety Instructions

Critical safety warnings and precautions for installation, connection, operation, and maintenance of the inverter.

Outline

Features

Key capabilities and characteristics of the communication interface, including connectable units and program facilitation.

Function Overview

Summary of functions controllable via communication, such as operation commands, frequency setting, and data monitoring.

Transmission Specification

Connection

Connection Method

Details on wiring between the inverter and host unit using shielded wires for communication.

RS485 Interface Details

Specifics of the RS485 interface for multi-drop bidirectional communication, including 2-wire and 4-wire connections.

Transmission Method

Transmission Frame Overview

Explanation of polling/selecting system and frame lengths for standard and option frames.

Standard Frame Structure

Detailed breakdown of the structure and fields within a standard communication frame.

Option Frame Structure

Detailed breakdown of the structure and fields within an option communication frame.

Negative Response Frame

Format and causes for negative response frames indicating communication errors.

Field Description

Data Field

Description of the data content within communication frames, including hexadecimal notation and data types.

Check Sum Field

Explanation of the check sum field used for error detection in communication frames.

Procedure on the Host Side

Polling Procedure

Flowchart and steps for the host unit to request data from the inverter.

Selecting Procedure

Flowchart and steps for the host unit to send data or commands to the inverter.

Example of Communication

Standard Frame Examples

Practical examples illustrating standard frame communication for frequency setting and polling.

Option Frame Examples

Practical examples illustrating option frame communication for operation commands and polling.

Communication Error

Communication Error Codes

List and description of various communication error codes detected by the inverter.

Action at Communication Error

Inverter's response and actions taken when specific communication errors occur.

Functions Specific for Communication

Command Data

Details on specific commands for controlling inverter functions via communication.

Operation Command Data

Commands related to inverter operation modes, such as FWD/REV and universal I/O.

Function Data

Data codes and descriptions for inverter parameters like acceleration and deceleration times.

Monitoring Data

List of inverter status data available for monitoring via communication.

Function Data Format

List of Function Data Format

Comprehensive list of function codes and their corresponding data formats.

Data Format Specification

Detailed explanation of how data is represented in communication frames, including integer and decimal formats.

Changeover of Communications

Changeover Method for Communication Valid/Invalid

Method to switch communication modes using multi-function terminals.

Link Function (Operation Selection)

Configuration for link function and operation selection based on H30 setting.

Coexistence of Link and RS485 Communication

Interaction and restrictions when link options are mounted with RS485 communication.

Response Time

Response Interval Time

Setting the time for the inverter to start sending a response after receiving a request.

Time of Receiving Preparation Completion

Time required for the inverter to complete receiving preparation of the input port.

Function Parameters

Serial Link (Function Selection)

Configuration settings for the serial communication link function.

RS485 Address Setting

Setting the station address for RS485 communication to match the system.

RS485 Response Interval Setting

Setting the response interval for RS485 communication for error handling.

Troubleshooting

Appendix

Communication Level Converter

Specifications for recommended communication level converters for RS232C to RS485.

ASCII Code List

A list of ASCII character codes and their hexadecimal representations.

Example of a Control Program

A sample QBasic program demonstrating communication with the inverter.