QUICK GUIDE
PUMP CONTROL
Frequency inverter for pump control and HVAC applications
Date Version
14/04/2009 1.0.5

Other manuals for Fuji Electric FRENIC-Eco Series

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric FRENIC-Eco Series and is the answer not in the manual?

Fuji Electric FRENIC-Eco Series Specifications

General IconGeneral
Output Voltage Range0 to Input Voltage
Power Supply Frequency50/60 Hz ±5%
Input Voltage200-240V AC (3-phase), 380-480V AC (3-phase)
Output Frequency0.1 to 400 Hz
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Overload Capacity150% for 60 seconds
CommunicationRS-485, Modbus RTU
Cooling MethodFan cooling
Operating Temperature Range-10°C to +50°C
Storage Temperature Range-20°C to +65°C
Altitude1000 m above sea level or less

Summary

Chapter 0: Introduction to pressure control systems

Regulation by means of PID control

Explanation of PID control, set value (SV), process value (PV), and error calculation.

Chapter 1: Single pump control

Single Pump Control Schematic

Diagram illustrating the wiring for a single pump control setup.

Sleep and Wake-up Functions

Functions to stop pump at low flow and restart it based on pressure demand.

Common Parameters and Descriptions

Overview and detailed explanation of parameters for pump control.

Chapter 2: Mono-regulated pump control with 1 regulated pump + 1, 2, 3 or 4 auxiliary pumps

Mono-regulated Pump Control Schematics

Diagrams for control schemes with 1 to 4 auxiliary pumps.

Auxiliary pump connection and disconnection

Conditions and process for connecting/disconnecting auxiliary pumps.

Chapter 3: Mono-regulated pump control with 1 regulated pump + 4 auxiliary pumps + 1 additional pump

Additional pump connection and disconnection

Conditions for connecting/disconnecting the additional pump.

Chapter 4: Multi-regulated pump control with 2/3 regulated pumps

Multi-regulated Pump Control Schematics

Diagrams for control schemes with 2 or 3 regulated pumps.

Pump connection and disconnection to main supply

Requirements for connecting/disconnecting pumps to the commercial power supply.

Chapter 5: Multi-regulated pump control with 3 regulated pumps + 1 additional pump

Additional pump connection and disconnection

Conditions for connecting/disconnecting the additional pump.

Chapter 6: Various Functions

Dry well function

Stops inverter if motor torque decreases below a set level for a period.

Overpressure alarm

Stops inverter and displays error if pressure rises above a set level.

Integral PID component hold

Holds PID integral component when pump sleeps to avoid overshoot.

Chapter 7: Complete Function Codes' List

Function Codes Overview

Comprehensive list of all function codes, their data setting ranges, and default values.

Chapter 8: Operation using the TP-E1 keypad

TP-E1 Keypad Overview and Operation Modes

Description of the keypad, its buttons, and the three operation modes.

Chapter 9: Option relay Card OPC-F1-RY

Relay Functions Assignment

List of functions that can be assigned to the relay outputs on the card.