36
9 Function
♦
The link function (communication function) can
connect RS485 (provided as standard) to various bus
connections (option).
The link function includes:
1) Monitoring
(various data monitoring and function data
check)
2) Frequency setting
3) Operation commands
(Commands such as FWD and REV set at the digital inputs)
4) Writing function data
H
HH
H
3
33
3
0
00
0
L I N K F U N C
Setting link function when communication is valid
Setting
value
Frequency
setting
Operation
command
0 Invalid Invalid
1 Valid Invalid
2 Invalid Valid
3 Valid Valid
Monitoring function and writing function data function
are always valid. If making the communication of
digital input invalid, the state becomes similar to 0 of
the setting value. When option related to busses is
provided, this setting in the function becomes the
function selecting of the option, and the function of
RS485 is restricted only to monitoring and writing
function data. When not providing option, this setting
becomes function selecting of
RS
485
.
These set various conditions of the communication
through RS485. Set these so as to match with
upstream devices. For the protocols, refer to the
technical manual.
♦
Setting the station address of RS485
H
HH
H
3
33
3
1
11
1
4 8 5 A D D R E S S
Setting range 1 – 31
♦
Setting action when occurring error and value of
timer for the action
H
HH
H
3
33
3
2
22
2
M O D E O N E R
H
HH
H
3
33
3
3
33
3
T I M E R
Setting
value
Processing at transmission error
0 Immediate Er8 alarm (forced stop)
1
Continue operation within timer
time,after timer time, Er8 alarm
2
Continue operation within timer time,
and retry operation After timer time,
Er8 alarm if communication error or
continue operation if no error
3 Continue operation
♦
Setting transmission speed
H
HH
H
3
33
3
4
44
4
B A U D R A T E
Setting
value
Transmission
speed
0 19200 bits/s
1 9600 bits/s
2 4800 bits/s
3 2400 bits/s
4 1200 bits/s
♦
Setting data length
H
HH
H
3
33
3
5
55
5
L E N G T H
Setting
value
Data length
0 8 bits
1 7 bits
♦
Setting parity bits
H
HH
H
3
33
3
6
66
6
P A R I T Y
Setting
value
Parity bit
0 Non
1 Even number
2 Odd number
♦
Setting stop bits
H
HH
H
3
33
3
7
77
7
S T O P B I T S
Setting
value
Stop bits
0 2 bits
1 1 bit
∼
∼
H39 RS485 (Response interval)
H30 Serial link (Function selection)
H31 RS485 (Address)