EasyManua.ls Logo

Fuji Electric NRF51 - Wi-Fi Communication

Fuji Electric NRF51
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TN5A4215b 26/58
4.4 Communication function
4.4.1 Wi-Fi communication function
4.4.1.1 Instructions for use
(1) The following settings are required in NRF51 in order that Wi-Fi communication is active.
Transmission interval: [2 seconds], [4 seconds], [10 seconds], [30 seconds] or [1 minute] (selectable)
Data format: [Type1], [Type2] or [Type3] (selectable)
Encryption: [WPA], [WPA2], [WEP] or [No encryption] (selectable)
Protocol: [UDP] or [TCP] (selectable)
IP address mode: [DHCP] or [Fixed address] (selectable)
*If “Fixed address” is selected, Local IP address, Subnet mask and Gateway settings are needed.
SSID: Up to 31 characters (see access point label)
Network key: Up to 32 characters (see access point label)
Host IP address: [0 to 255, 0 to 255, 0 to 255, 0 to 255] (IP address of server)
Port No.: 0 to 65535 (Opened port No. of server)
(2) Wi-Fi communication setting should be “ON” by user with Dosimeter Configuration Tool.
(3) When the setting is ON”, NRF51 starts connection with cloud server via Wi-Fi access point. After
connection establishment, NRF51 sends telemetry data with selected transmission interval and data
format.
4.4.1.2 Specification
Operating time: More than 8 hours (New alkaline two batteries are used and transmission interval is
“10 seconds”)
*“Low battery voltage” alarm generates if Wi-Fi communication stops because of low battery in use.
When the alarm occurs, please exit from radiation controlled area immediately and replace the batteries
with new ones.
*Use of two batteries is recommended in order to keep stable communication status though NRF51
can be used by one battery.