EasyManua.ls Logo

Fuji Electric PXZ Series - Controller Functional Parts

Fuji Electric PXZ Series
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
4 Usage (Read before using)
Name of Functional Parts and Functions
C
C○
PV
○
H○
L○
PXZ-4
SEL DATA ENTPV/SV
SV
○
Model:PXZ4
13
12
8
6
18
4
7
9
10
11
2
14
10
17
16
Model:PXZ5
C
C1
○
C2
○
H
○
L
○
HB
○
PV
SV
○
DATASEL
ENTSV
15
12
4
11
5
9
10
6
1413
1
3
2
7
8
Model:PXZ7,9
14
8
65
1
7
2
4
11
9
3
151312
C
C1○
PV
SV
○
C2○H○ HB○
L○
PXW-7
SEL DATA ENTSV
PXW-5
Name
q Measured value (PV) display
w Set value (SV) indication lamp
e Set value (SV) parameter display
r DOWN key (common for each
digit)
t Direct SV key
y SELECT key
u Data display key
i Data entry key
o UP key for first place
!0 UP key for second place
!1 UP key for third place
!2 Control output indication lamp
!3 Upper limit alarm indication lamp
(option)
!4 Lower limit alarm indication lamp
(option)
!5 Heater burnout alarm
indication lamp (option)
!6 Measured value (PV)/set value
(SV) parameter display
(applicable to PXZ4 only)
!7 Measured value (PV) indication
lamp
!8 PV/SV SELECT key (for PXZ4
only)
Function
Displays a measured value (PV).
Stays on while a set value (SV) is on the display.
Parameter symbols and codes are displayed for a set value (SV)
and when setting various parameters.
Decrements the numerical value in the place selected with the UP
key. Where various parameters are displayed, each parameter is
displayed one by one every time this key is pressed. The sequence
of displays, however, is just opposite to the sequence of displays
with the SEL key.
By pressing this key, a set value (SV) is displayed.
The key to be used when switching over to the 1st or 2nd block
parameters, or when moving parameters within a block.
Displays the data assigned to the parameter selected with the SEL
key.
The key to be used for storing the data after previous data is
changed. (None of changed data can be registered unless this key
is pressed.)
By pressing once, a number in the units place blinks. The number is
continuously incremented with the key kept on pressing
By pressing once, a number in the tens place blinks. The number is
continuously incremented with the key kept on pressing.
By pressing once, a number in the hundreds place blinks. The
number is continuously incremented with the key kept on pressing.
A numeric "9" is followed by "0" and, concurrently, a number of the
thousands place is incremented by 1.
C : Comes on when the control output is ON.
C1: Comes on when the control output 1 is ON.
C2: Comes on when the control output 2 is ON.
Comes on when the upper limit alarm is activated. Blinks while
setting the alarm value.
Comes on when the lower limit alarm is activated. Blinks while
setting the alarm value.
Comes on when the heater burnout alarm is output. Blinks while
setting the detection/activation value.
Parameter symbols and codes are displayed for measured value
(PV) and set value (SV) and when setting various parameters.
Stays on while measured value (PV) is on display.
The display of measured value (PV) and set value (SV) is switched
over every time this key is pressed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Other manuals for Fuji Electric PXZ Series