3.18 Not Detecting Multifeed for Fixed Format
Auto-cancel Timer:
Scanning is not restarted for the set period of time (minutes) after a multifeed error. If scanning is not
started after the set minutes, the application is notified of the error by the driver. Note that if the Auto-
cancel Timer is set to 0, the application will never be notified of the error.
3. In the Software Operation Panel or driver dialog box, select [Check Overlapping] or [Check
Overlapping and length difference]. In addition, specify an area in which a multifeed error is
detected, under [Document check area specification] (Preferences) in the Software Operation
Panel dialog box.
The Intelligent Multifeed Function bypasses multifeed errors within the specified area.
4. Select [Intelligent Multifeed Setting] in the Software Operation Panel, and then select one of the
three modes described above.