Item Explanation Selectable parameter Default
Page counter
(Consumables
counter)
For evaluating the
consumable replacement
cycle.
Use this function to reset
the counters after replacing
consumables.
Pick roller/Brake roller/remaining ink
level (only for the imprinter option)
—
Power saving setting Select the waiting time
before entering the Power
saving mode.
Setting range 15 to 55 minutes (set in
steps of 5 min.)
15 min.
Offset setting
Adjust the start position for
the document scanning.
Up down/Left right: setting range -2
to 2 mm (set in 0.5 mm steps)
Up down/
left right : 0
mm
Scan scale Adjust the magnification in
the feeding direction.
Setting range -3.1% to 3.1% (set in
0.1% steps)
0%
Device settings 2
Selecting each item displays detailed settings (parameters) in the right part of the dialog box.
file:///D|/Documents%20and%20Settings/scanner/Desktop/Lynx3/06/contents/EN/08/c08_01_01.htm (3 of 5)9/28/2007 2:38:49 PM