- (02 - 22) -
OUTDOOR UNIT
AO
G14-18L2
OUTDOOR UNIT
AO
G14-18L2
INDOOR UNIT : 7000Btu (AO
G18L2)
COOLING
Pipe length (m)
3 5 10 15 20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15 - - - 0.940 0.914
10 - - 0.973 0.948 0.921
5 - 0.988 0.977 0.952 0.925
3 0.992 0.992 0.981 0.956 0.929
0 1.000 1.000 0.989 0.963 0.936
Û
2
Indoor unit
is lower than
outdoor unit
-3 1.000 1.000 0.989 0.963 0.936
-5 - 1.000 0.989 0.963 0.936
-10 - - 0.989 0.963 0.936
-15 - - - 0.963 0.936
HEATING
Pipe length (m)
3 5 10 15 20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15 - - - 0.942 0.925
10 - - 0.959 0.942 0.925
5 - 1.000 0.959 0.942 0.925
3 0.990 1.000 0.959 0.942 0.925
0 0.990 1.000 0.959 0.942 0.925
Û
2
Indoor unit
is lower than
outdoor unit
-3 0.985 0.995 0.954 0.937 0.920
-5 - 0.993 0.952 0.935 0.919
-10 - - 0.949 0.933 0.916
-15 - - - 0.928 0.911