EasyManua.ls Logo

Fujitsu AB*G14LVTA - Safety Devices

Fujitsu AB*G14LVTA
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- (02 - 33) -
OUTDOOR UNIT
AO
G14-18L2
OUTDOOR UNIT
AO
G14-18L2
SAFETY DEVICES11.
Protection form
Model
AO
Û
G14L2 AO
Û
G18L2
Circuit protection
Current fuse (MAIN PCB)
15A 250V
10A 250V
3.15A 250V
Current fuse
(NEAR THE TERMINAL)
20A 250V
Fan motor protection Thermal protector
OFF :100
+15
°C
-10
ON : 95
+15
°C
-10
Compressor protection
Thermal protection program
(DISCHARGE TEMP.)
OFF : 110°C
ON : 80°C
Thermal protection program
(Compressor bottom TEMP.)
OFF : 110°C
ON : 80°C
Refrigerant circuit protection
Thermal protection program
(HEAT EXCHANGER TEMP.)
OFF : 67°C
ON : 59°C