- (02 - 24) -
OUTDOOR UNIT
AO
G14-18L2
OUTDOOR UNIT
AO
G14-18L2
INDOOR UNIT : 9000Btu (AO
G18L2)
COOLING
Pipe length (m)
3 5 10 15 20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15 - - - 0.928 0.898
10 - - 0.966 0.936 0.905
5 - 0.988 0.969 0.940 0.909
3 0.992 0.992 0.973 0.943 0.912
0 1.000 1.000 0.981 0.951 0.920
Û
2
Indoor unit
is lower than
outdoor unit
-3 1.000 1.000 0.981 0.951 0.920
-5 - 1.000 0.981 0.951 0.920
-10 - - 0.981 0.951 0.920
-15 - - - 0.951 0.920
HEATING
Pipe length (m)
3 5 10 15 20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15 - - - 0.942 0.924
10 - - 0.959 0.942 0.924
5 - 1.000 0.959 0.942 0.924
3 0.990 1.000 0.959 0.942 0.924
0 0.990 1.000 0.959 0.942 0.924
Û
2
Indoor unit
is lower than
outdoor unit
-3 0.985 0.995 0.954 0.937 0.919
-5 - 0.993 0.952 0.935 0.918
-10 - - 0.949 0.932 0.915
-15 - - - 0.928 0.910
H
H
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe