EasyManua.ls Logo

Fujitsu AB*G14LVTA - Page 292

Fujitsu AB*G14LVTA
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- (04 - 08) -
OUTDOOR UNIT
AO
G30L4
OUTDOOR UNIT
AO
G30L4
Heating
z
Combination
of indoor unit
HEATING OPERATION
Heating Capacity
Input Power
(min-max)
COP
Seasonal Data
Room 1 Room 2 Room 3 Room 4
Total Capacity
(min-max)
Pdesign
SCOP
Energy
Efciency
Class
KW KW KW KW KW KW kW
3 Room
7 7 14 - 2.42 2.42 4.15 - 9.00 ( 1.8 - 10.1 ) 2.66 ( 0.58 - 3.53 ) 3.38 5.8 3.8 A
7 7 18 - 2.27 2.27 4.86 - 9.40 ( 3.3 - 11.2 ) 2.46 ( 0.87 - 3.52 ) 3.82 5.8 3.8 A
7 7 24 - 2.03 2.03 5.44 - 9.50 ( 3.3 - 11.5 ) 2.47 ( 0.87 - 3.52 ) 3.85 5.8 3.8 A
7 9 12 - 2.49 2.94 3.56 - 9.00 ( 1.8 - 10.0 ) 2.69 ( 0.58 - 3.51 ) 3.35 5.8 3.8 A
7 9 14 - 2.33 2.75 4.00 - 9.10 ( 3.3 - 10.2 ) 2.64 ( 0.87 - 3.50 ) 3.45 5.8 3.8 A
7 9 18 - 2.17 2.56 4.66 - 9.40 ( 3.3 - 11.3 ) 2.45 ( 0.87 - 3.50 ) 3.84 5.8 3.8 A
7 9 24 - 1.98 2.33 5.29 - 9.60 ( 3.3 - 11.5 ) 2.46 ( 0.87 - 3.51 ) 3.90 5.8 3.8 A
7 12 12 - 2.33 3.33 3.33 - 9.00 ( 1.8 - 10.1 ) 2.66 ( 0.58 - 3.48 ) 3.38 5.8 3.8 A
7 12 14 - 2.22 3.17 3.80 - 9.20 ( 3.3 - 10.3 ) 2.62 ( 0.87 - 3.48 ) 3.51 5.8 3.8 A
7 12 18 - 2.08 2.97 4.45 - 9.50 ( 3.3 - 11.4 ) 2.44 ( 0.87 - 3.47 ) 3.89 5.8 3.8 A
7 12 24 - 1.88 2.69 5.03 - 9.60 ( 3.3 - 11.7 ) 2.45 ( 0.87 - 3.56 ) 3.92 5.8 3.8 A
7 14 14 - 2.10 3.60 3.60 - 9.30 ( 3.3 - 10.6 ) 2.59 ( 0.87 - 3.48 ) 3.59 5.8 3.8 A
7 14 18 - 1.96 3.35 4.19 - 9.50 ( 3.7 - 11.5 ) 2.42 ( 0.97 - 3.52 ) 3.93 5.8 3.8 A
7 14 24 - 1.78 3.05 4.77 - 9.60 ( 3.3 - 11.7 ) 2.45 ( 0.87 - 3.56 ) 3.92 5.8 3.8 A
7 18 18 - 1.82 3.89 3.89 - 9.60 ( 3.7 - 12.0 ) 2.40 ( 0.97 - 3.52 ) 4.00 5.8 3.8 A
7 18 24 - 1.65 3.53 4.42 - 9.60 ( 4.3 - 12.0 ) 2.40 ( 1.12 - 3.52 ) 4.00 5.8 3.8 A
9 9 9 - 3.00 3.00 3.00 - 9.00 ( 3.3 - 10.0 ) 2.69 ( 0.87 - 3.51 ) 3.35 5.8 3.8 A
9 9 12 - 2.80 2.80 3.39 - 9.00 ( 3.3 - 10.1 ) 2.67 ( 0.87 - 3.48 ) 3.37 5.8 3.8 A
9 9 14 - 2.66 2.66 3.87 - 9.20 ( 3.3 - 10.3 ) 2.63 ( 0.87 - 3.48 ) 3.50 5.8 3.8 A
9 9 18 - 2.49 2.49 4.52 - 9.50 ( 3.7 - 11.4 ) 2.44 ( 0.97 - 3.48 ) 3.89 5.8 3.8 A
9 9 24 - 2.25 2.25 5.11 - 9.60 ( 3.7 - 11.7 ) 2.45 ( 0.97 - 3.57 ) 3.92 5.8 3.8 A
9 12 12 - 2.65 3.22 3.22 - 9.10 ( 3.3 - 10.3 ) 2.65 ( 0.87 - 3.52 ) 3.43 5.8 3.8 A
9 12 14 - 2.53 3.07 3.69 - 9.30 ( 3.3 - 10.5 ) 2.61 ( 0.87 - 3.52 ) 3.56 5.8 3.8 A
9 12 18 - 2.36 2.86 4.29 - 9.50 ( 3.7 - 11.4 ) 2.43 ( 0.97 - 3.47 ) 3.91 5.8 3.8 A
9 12 24 - 2.14 2.59 4.86 - 9.60 ( 3.7 - 11.8 ) 2.44 ( 0.97 - 3.55 ) 3.93 5.8 3.8 A
9 14 14 - 2.38 3.46 3.46 - 9.30 ( 3.7 - 10.7 ) 2.58 ( 0.97 - 3.46 ) 3.60 5.8 3.8 A
9 14 18 - 2.22 3.23 4.04 - 9.50 ( 3.7 - 11.6 ) 2.41 ( 0.97 - 3.51 ) 3.94 5.8 3.8 A
9 14 24 - 2.03 2.95 4.62 - 9.60 ( 4.3 - 11.9 ) 2.42 ( 1.12 - 3.57 ) 3.97 5.8 3.8 A
9 18 18 - 2.07 3.76 3.76 - 9.60 ( 4.3 - 12.0 ) 2.40 ( 1.12 - 3.52 ) 4.00 5.8 3.8 A
12 12 12 - 3.07 3.07 3.07 - 9.20 ( 3.3 - 10.3 ) 2.63 ( 0.87 - 3.49 ) 3.50 5.8 3.8 A
12 12 14 - 2.91 2.91 3.49 - 9.30 ( 3.3 - 10.6 ) 2.59 ( 0.87 - 3.49 ) 3.59 5.8 3.8 A
12 12 18 - 2.71 2.71 4.07 - 9.50 ( 3.7 - 11.6 ) 2.42 ( 0.97 - 3.52 ) 3.93 5.8 3.8 A
12 12 24 - 2.48 2.48 4.65 - 9.60 ( 3.7 - 11.8 ) 2.43 ( 0.97 - 3.54 ) 3.95 5.8 3.8 A
12 14 14 - 2.76 3.32 3.32 - 9.40 ( 3.7 - 10.8 ) 2.40 ( 0.97 - 3.50 ) 3.92 5.8 3.8 A
12 14 18 - 2.57 3.08 3.85 - 9.50 ( 3.7 - 11.6 ) 2.40 ( 0.97 - 3.49 ) 3.96 5.8 3.8 A
12 18 18 - 2.40 3.60 3.60 - 9.60 ( 4.3 - 12.0 ) 2.40 ( 1.12 - 3.52 ) 4.00 5.8 3.8 A
Notes:
7:7000Btu/h, 9:9000Btu/h, 12:12000Btu/h, 14:14000Btu/h, 18:18000Btu/h, 24:24000Btu/h models.
The above is the value for connecting with Wall Mounted type.
3 or more indoor units should be connected.
Heating capacity is based on 20 °CDB (indoor temperature), 7 °CDB/6 °CWB (outdoor temperature).
Pipe l ength : 5m, Height difference : 0m. (Outdoor unit to indoor unit)
The total ability of connected a indoor unit is up to 49000 Btu from 27000 Btu.